HP XP Command View Advanced Edition Software User Manual
Page 117
![background image](/manuals/397820/117/background.png)
Command line interface commands
117
Table 4-40
GetStorageArray (subtarget=LDEV) command parameters
Parameter Name Status
Description
model
Optional
Model of the storage subsystem
If you omit this parameter, all the storage subsystems become the target.
serialnum
Optional
Serial number of the storage subsystem
If you omit this parameter, all the storage subsystems become the target.
subtarget
Required
Specify LDEV.
devnum
Optional
Device number of the LDEV that you intend to obtain
Specify this parameter when you want to obtain information about a
specific LDEV. If you specify this parameter, you must also specify the
model
and serialnum parameters. If you specify the model and
serialnum
parameters, and omit the devnum parameter, information
about all the LDEVs in the specified storage subsystem is obtained.
This parameter can be specified in decimal, and in colon-separated
hexadecimal. If you specify a hexadecimal number, for
XP12000/XP10000/SVS200, XP1024/XP128, and XP512/XP48, use the
xx:yy format, where xx is the CU number, and yy is the LDEV number.
For XP24000/XP20000, use the ww:xx:yy format, where ww is the LDKC
number, xx is the CU number, and yy is the LDEV number. ww is optional.
If you omit ww, the LDKC number is regarded as 0.
NOTE:
The execution results are output in decimal.
ldevfilter
Optional
Filter used for selecting the LDEV
Available values are OPEN, INTERMEDIATE, and MAINFRAME, which are
not case-sensitive. To specify two or more values, separate them with a
semicolon (;). If you omit this parameter, all LDEVs are displayed. When
you specify OPEN, the LDEVs for an open volume will be displayed. When
you specify INTERMEDIATE, the LDEVs for an intermediate volume will
be displayed. When you specify MAINFRAME, the LDEVs for a mainframe
volume will be displayed. When you specify OPEN; MAINFRAME, the
LDEVs for both the open volume and mainframe volume will be displayed.
ldevsubinfo
Optional
Information about the LDEV
The value you can specify is VolumeConnection.
startElementNum
Filter
Optional
Starting sequence number of logical devices for which information is to be
obtained
Specify this parameter when you want to obtain information for a part of
logical devices in a specific storage subsystem.
When logical device information is ordered by device number (in
ascending order) from 0, specify the first number in the sequence of
logical devices that you want to obtain.
This parameter must be specified together with the
numOfElementsFilter
, model, and serialnum parameters.
numOfElementsFi
lter
Optional
Number of logical devices for which information is to be obtained
Specify this parameter when you want to obtain information for a part of
logical devices in a specific storage subsystem. Specify the number of
logical devices for which information is to be obtained. This parameter
must be specified together with the startElementNumFilter, model,
and serialnum parameters.
The maximum recommended value is 16384.