HP XP Command View Advanced Edition Software User Manual
Page 122

Command line interface commands
122
Table 4-42
GetStorageArray (subtarget=LogicalUnit) command parameters
Parameter Name Status
Description
ldevsubinfo
Optional
Information about the LDEV
The value you can specify is VolumeConnection. If you specify this
parameter, you must also specify the lusubinfo=LDEV.
thpvolfilter
Optional
Filter for selecting a THP volume
Specify either the pool ID of a THP pool, or Unassigned. If you specify
the pool ID of a THP pool, information about the THP volumes assigned to
that THP pool is obtained.
If you specify Unassigned, information about THP volumes not assigned
to a THP pool is obtained.
NOTE:
This information cannot be obtained by the partitioned storage
administrator.
NOTE:
If you specify model and serialnum at the same time, the
specification for this parameter becomes invalid.
startElementNum
Filter
Optional
Starting sequence number of logical units for which information is to be
obtained
Specify this parameter when you want to obtain information for a part of
logical units in a specific storage subsystem.
When the logical unit information is ordered by device number (in
ascending order) from 0, specify the first number in the sequence of
logical units that you want to obtain.
This parameter must be specified together with the
numOfElementsFilter
, model, and serialnum parameters.
numOfElementsFi
lter
Optional
Number of logical units for which information is to be obtained
Specify this parameter when you want to obtain information for a part of
logical units in a specific storage subsystem. Specify the number of logical
units for which information is to be obtained. This parameter must be
specified together with the startElementNumFilter, model, and
serialnum
parameters.
The maximum recommended value is 16384.
Command execution example: In this example, the CLI command obtains information about the
logical units in a storage subsystem (serial number: 10001, model: XP12000). The information
includes information about the paths to the logical units, the LDEVs used in the logical units, the
WWNs of the path, the WWN groups, and the host.
hdvmcli GetStorageArray -o "D:\logs\XP12000 GetStorageArray_LogicalUnit.log"
"subtarget=LogicalUnit" "model=XP12000" "serialnum=10001" "lufilter=all"
"lusubinfo=Path,LDEV,VolumeConnection" "pathsubinfo=wwn,wwngroup,hostinfo"
"ldevsubinfo=VolumeConnection"
Command execution result:
RESPONSE:
An instance of StorageArray
.
. (Attributes of StorageArray are omitted here)
.
List of 1752 Lu elements:
An instance of LogicalUnit
objectID=*****
devNum=100
displayName=00:64
emulation=OPEN-3