15

Table 1

Revisions

Date Edition

Revision

Edition or Windows Server 2003 R2 x64 Edition, Device Manager CLI must
be used on the same machine as the Device Manager server.

Device Manager CLI now supports XP24000 as a new storage subsystem.

The message displayed when a memory shortage occurs in Device
Manager CLI has been changed.

In case of an occasion when the Device Manager database becomes
inconsistent due to the function of dividing a database operation into
transactions, the solution of this problem has been added to the explanation
of the command.

A note has been added for the case that information of the target
component is not output even if the GetStorageArray command is
executed with the subtarget parameter specified.

The GetStorageArray (subtarget=LogicalDKC) command, which
obtains the information about a logical DKC, has been added.

The method to obtain the pdevid parameter values in advance has been
changed.

The startElementNumFilter and numOfElementsFilter
parameters, which are used for obtaining partial information, have been
added.

Notes on specifying the domain, domainnickname, port, and portname
parameters have been added.

The recommended maximum configuration for using the AddLunScan
command has been added.

Along with the logical DKC support, the format of LDKC:CU:LDEV has
been added to the hexadecimal specification of the devnum parameter.

The following notes have been added to command explanations of the
command:

The capacity of the LDEV to be created will be larger than the specified
capacity.

The SSID must be obtained before an LDEV or LU is created.

The following note has been added to command explanations of the
command:

When a LUSE is created, formatted LDEVs must be specified.

Descriptions have been added that explain the values that can be specified
for the adaptermode parameter of the ModifyPortController
command.

Along with the logical DKC support, the format of LDKC:CU:LDEV has
been added to the hexadecimal specification of the pvoldevnum and
svoldevnum

parameters.

A description has been added, which shows that the pairoption
parameter can be specified only when XP12000/XP10000/SVS200 is being
used.

A description about XP24000 has been added to the explanation of the
chassis

, emulation, diskType, controllerID, slprNumber,

clprNumber

, and cuInfo attributes of the ArrayGroup instance.

The following attributes have been added to the ArrayGroup instance:

openAllocatedActualCapacity

openUnallocatedCapacity

openUnallocatedActualCapacity

openReservedCapacity

openReservedActualCapacity