background image

OPERATION

81

Display

2.596

V

500.06

mA

1.2982

w

CV B Value

15.000

CV A Value

15.000

LOAD

RS232

A Value

Fine

03/Sep/2012

V

V

OCP Alarm

Please Press Enter

To Clear Alarm

OCP

OCP indicator

Alarm message
when OCP is set
to Load Off

Mode

CV

I Range

L 0.7A

V Range

L 15V

Response

Fast

Configure

OPP

Description

For OPP, the PEL-3000 can be configured to
either limit the power or turn off the load.

The OPP levels can be set to 10% higher than
the rating power.

Operation

1. Press

Main

> Configure[F5] > Protection[F1]

and set the OPP Level and OPP Setting.

Range:

OPP Level: Rating power + 10%
OPP Setting: LIMIT, Load Off

Alarm

When OPP Setting is configured to Load Off, a
message will be displayed on the screen when
OPP is tripped. The Enter key must be pressed
to clear the alarm message.

When configured to LIMIT, OPP will be
displayed on the screen when the OPP is tripped
and the power will be limited to the OPP Level
setting.