beautypg.com

Dynamic mode – GW Instek PEL-3000 Series User Manual User Manual

Page 202

background image

PEL-3000 User Manual

200

Ammeter
H, M Range 0.000A~35.000A

0.000A~70.000A

0.00A~210.00A

L Range

0.00mA~350.00mA

0.00mA~700.00mA

0.0mA~2100.0mA

Accuracy

±(0.2 % of rdg + 0.3 % of f.s)

Accuracy

Parallel Operation: ±(1.2% of rdg +1.1% of f.s.)

Wattmeter
H, M Range 0.00W~175.00W

0.00W~350.00W

0.00W~1050W

L(CC/CR/CV
mode)

0.000W~52.500W

0.000W~ 105.000W

0.00W~315.00W

L(CP mode) 0.0000W~ 1.7500W

0.0000W~ 3.5000W

0.000W~ 10.500W

Temperature Coefficient per ºC
Voltmeter

100ppm

Ammeter

200ppm

Dynamic Mode

Model

PEL-3021

PEL-3041

PEL-3111

Operating Mode

CC, CR and CP

T1 & T2

0.025ms ~ 10ms / Res: 1us

10ms ~ 30s / Res: 1ms

Accuracy

1us / 1ms ± 100ppm

Frequency Range (Freq./Duty)

1Hz ~20kHz

Frequency Resolution
1Hz~9.9Hz

0.1Hz

10Hz~99Hz

1Hz

100Hz~990Hz

10Hz

1kHz~20kHz

100Hz

Frequency Accuracy of Setting

(0.5% of set)

Duty Cycle of Setting (Freq./Duty)

1% ~99% , 0.1% step

The minimum time width is 10 us. Between 1kHz and 20kHz, the
maximum duty cycle is limited by the minimum time width.

Slew Rate Setting Range (CC Mode)
H Range

2.5mA/us~2.5A/us

5mA/us~5A/us

16mA/us~16A/us

M Range

250uA/us~250mA/us 500uA/us~500mA/us 1.6mA/us~1.6A/us

L Range

25uA/us~25mA/us

50uA/us~50mA/us

160uA/us~160mA/us