beautypg.com

Soft start, Remote sensing – GW Instek PEL-3000 Series User Manual User Manual

Page 204

background image

PEL-3000 User Manual

202

Resistance Accuracy of setting
H, M Range

±(0.5 % of set

*1

+ 0.5 % of f.s

*2

) + Vin

*3

/500 kΩ

L Range

±(0.5 % of set

*1

+ 0.5 % of f.s) + Vin

*3

/500 kΩ

*1

set = Vin / Rset

*2

f.s. = Full scale of High Range

*3

Vin = Input terminal voltage of Electronic Load

Power Operating Range
H Range

17.5W
~175W

35W~350W

105W
~1050W

M Range

1.75W
~17.5W

3.5W~35W

10.5W
~105W

L Range

0.175W
~1.75W

0.35W~3.5W

1.05W
~10.5W

Setting Range
H Range

0W~178.5W

0W~357W

0W~1071W

M Range

0W~17.85W

0W~35.7W

0W~107.1W

L Range

0W~1.785W

0W~3.57W

0W~10.71W

Resolution
H Range

10mW

10mW

100mW

M Range

1mW

1mW

10mW

L Range

0.1mW

0.1mW

1mW

Accuracy of Setting

*1

±(0.6 % of set + 1.4 % of f.s

*2

)


*1 It is not applied for the condition of the parallel operation.
*2 M range applies to the full scale of H range.

Soft Start

Operation Mode

CC, CR and CP

Selectable Time Range

1~ 200 ms/Res: 1ms

Time Accuracy

±(30%of set + 100us)

Remote Sensing

Voltage that can be Compensated

2V for a single line