beautypg.com

GW Instek PEL-3000 Series User Manual User Manual

Page 146

background image

PEL-3000 User Manual

144

Example

The LoadOn IN setting determines whether the
load is turned on when the external switch is
closed (low) or open (high).

High

Low

High

Low

LoadOn In = High

Load

On

Off

Load on

Load off

LoadOn In = Low

Operation:
Configuration

1. Press

Main

> Configure [F5] > Next Menu [F4]

> External [F3] and set the LoadOn IN setting.

Set to Low if you want the load to be turned on
when the switch is closed.

Set to High if you want the load to turn on when
the switch is open.

Note

When external control is used to turn the load off,
the load key cannot be used to turn the load on.
However the reverse is not true. If the load has
been turned on by external control, the load key
can be used to turn the load off.