beautypg.com

Short control – GW Instek PEL-3000 Series User Manual User Manual

Page 151

background image

EXTERNAL CONTROL

149

Alarm Status

Description

Pins 16 and 17 of the J1 connector are used to
monitor whether the alarm is on or off.

Pin out

The Alarm Status pin
is a photo-coupled
open-collector
output.

17

16

Photocoupler input: 30V max, 8mA, max.

Short Control

Description

The Short Signal Out pins (19 and 20) are
30VDC 1A relay contact outputs. These outputs
can be used to drive an external relay to
physically short the terminal outputs.

Pin Inputs

The Short Signal Out pins are normally open
until the short function is activated.

PEL-3000

External

relay driver

20

19

NO

J1

connector

Input

Terminals

NO

Note

The external relay driver is not a standard
accessory. Please provide your own external relay
and driver circuit.