72

Von Voltage Latch

Description

When Von Latch is set to ON, the load will
continue to sink current after being ―latched‖,
even if the voltage drops below the Von
Voltage threshold level.

When Von Latch is set to OFF, the load will
turn off when the voltage drops below the Von
Voltage threshold level.

By default Von Latch is set to OFF.

Time

Von Latch = OFF

Von

V

Time

I

PEL-3000

V out

Load on

Load off

Load on

Time

Von Latch = ON

Von

V

Time

I

PEL-3000

V out

Load on

Operation

1. Press

Main

> Configure[F5] > Other[F2] and

set the Von Latch setting.

Range:

Von Latch: OFF, ON