beautypg.com

Cv mode response speed – GW Instek PEL-3000 Series User Manual User Manual

Page 70

background image

PEL-3000 User Manual

68

Display

Mode

CC

I Range

H 35A

V Range

H 150V

Function

Dynamic

Configure

0.00

V

0.000

A

0.00

w

Timer1

0.025

SlewRate

2500.00

SlewRate

2500.00

LOAD

RS232

03/Sep/2012

ms

mA/uS

mA/uS

Slewrate settings

Slewrate settings

CV Mode Response Speed

Description

The response speed setting is the response
speed for the negative feedback control of the
load current when used in CV mode. Response
speed settings are only applicable to CV mode.

A response speed that is too fast could cause the
unit to be unstable.

Reducing the response speed can improve
stability.

Operation

1. Make sure the load is off.

2. Press

Main

. Make sure the unit is in CV

mode by using the Mode[F1] soft-key.

3. Select the response speed with the Response[F4]

soft-key.

Range:

Slow, Fast