PEL-3000 User Manual
204
Fast Sequence
Operation
mode
CC or CR
Maximum
number of
steps
1000
Step
Execution
Time
25 μs – 600 ms
Time
resolution
1us(25us -60ms) /10us(60.01ms -600ms)
Other
Elapsed Time Delay
Measures the time from load on to load off. On/Off selectable.
Measures from 1 s up to 999 h 59 min 59 s
Auto Load Off Timer
Automatically turns off the load after a specified time elapses.
Can be set in the range of 1 s to 999 h 59 min 59 s or off
Communication Function
GPIB
IEEE std. 488.1-1978 (partial support)
SH1, AH1, T6, L4, SR1, DC1, DT1.
Supports the SCPI and IEEE std. 488.2-1992 command set
Sets panel functions except the power switch and reads measured
values
RS-232C
D-SUB 9-pin connector (conforms to EIA-232-D)
Sets panel functions except the power switch and reads measured
values
Supports the SCPI and IEEE std. 488.2-1992 command set
Baud rate: 2400, 4800, 9600, 19200, 38400 bps
Data length: 8-bit, Stop bit: 1, 2-bit, Parity bit: None, Odd, Even.
USB
Conforms to USB 2.0 Specifications and USB-CDC ACM
Sets panel functions except the power switch and reads measured
values
Communication speed 12 Mbps (Full speed)
Analog External Control
Load on/off Control Input
Turn on the load with low (or high) TTL level signal
Load on Status Output
On when the load is on (open collector output by a photocoupler)