36

7. Press Duty (F2), 25,

%(F5), Return (F6).

8. Press Scale (F3),

32767, Enter (F5),
Return (F6), Done
(F4).

ARB - Add Point

Example: ARB Mode, Add point, Address 40, data 30,000.

Output

1. Press ARB, Edit

(F2), Point (F1),
Address (F1).

2. Press 4 + 0 + Enter

(F5), Return (F6).

3. Press Data (F2),

3+0+0+0+0, Enter
(F5).

ARB - Add Line

Example: ARB Mode, Add line, Address:Data (10:30, 50:100)

Output

1. Press ARB, Edit

(F2), Line (F2), Start
ADD (F1).

2. Press 1 + 0 + Enter

(F5), Return (F6).