beautypg.com

Source[1]:sweep:state – GW Instek AFG-3000 Series User Manual

Page 242

background image

AFG-3000 Series User Manual

242

Select Sweep

Time

Select the sweep

trigger source

Select the marker

frequency

5. Choose the sweep time using the

SOURce[1]:SWE:TIME command.

6. Select an internal or external sweep trigger

source using the SOURce[1]:SOUR command.

7. To output a marker frequency from the SYNC

terminal, use The SOURce[1]:MARK:FREQ
command. To enable marker frequency
output, use the SOURce[1]:MARK ON
command.

The marker frequency can be set to a value within
the sweep span.

SOURce[1]:SWEep:STATe

Source Specific
Command

Description

Sets or disables Sweep mode. By default Sweep is
disabled. FM modulation must be enabled before
setting other parameters.

Note

Any modulation modes or Burst mode will be
disabled if sweep mode is enabled.

Syntax

SOURce[1]:SWEep:STATe {OFF|ON}

Example

SOUR1:SWE:STAT ON

Enables sweep mode.

Query Syntax

SOURce[1]:SWEep:STATe?

Return Parameter 0 Disabled

(OFF)

1 Enabled

(ON)

Example

SOUR1:SWE:STAT?
1

Sweep mode is currently enabled.