Query Syntax

SOURce[1]:SWEep:SPACing?

Return Parameter LIN Linear

spacing

LOG Logarithmic

spacing

Example

SOUR1:SWE:SPAC?
LOG

The spacing is currently set as linear.

SOURce[1]:SWEep:TIME

Source Specific
Command

Description

Sets or queries the sweep time. The default sweep
time is 1 second.

Note

The function generator automatically determines
the number of frequency points that are used for
the sweep based on the sweep time.

Syntax

SOURce[1]:SWEep:TIME
{|MINimum|MAXimum}

Parameter

1 ms ~ 500 s

Example

SOUR1:SWE:TIME +1.0000E+00

Sets the sweep time to 1 second.

Query Syntax

SOURce[1]:SWEep:TIME? {|
MINimum|MAXimum}

Return Parameter

Returns sweep time in
seconds.

Example

SOUR1:SWE:TIME?
+2.0000E+01

Returns the sweep time (20 seconds).