beautypg.com

Source[1]:ramp:symmetry – GW Instek AFG-3000 Series User Manual

Page 217

background image

REMOTE

INTERFACE

217

Sets the duty cycle to the highest possible for the
current frequency.

Query Syntax

SOURce[1]:SQUare:DCYCle? {MINimum|MAXimum}

Return Parameter

Returns the duty cycle as a
percentage.

Example

SOUR1:SQU:DCYC?

+5.00E+01

The duty cycle is set 50%.

SOURce[1]:RAMP:SYMMetry

Source Specific
Command

Description

Sets or queries the symmetry for ramp waves only.
The setting is remembered if the function mode is
changed. The default symmetry is 50%.

Note

For ramp waveforms, the Apply command and
AM/FM modulation modes ignore the current
symmetry settings.

Syntax

SOURce[1]:RAMP:SYMMetry {< percent>
|MINimum|MAXimum}

Example

SOUR[1]:RAMP:SYMM MAX

Sets the symmetry to the 100%.

Query Syntax

SOURce[1]:RAMP:SYMMetry?
{MINimum|MAXimum}

Return Parameter

Returns the symmetry as a
percentage.

Example

SOUR1:RAMP:SYMMetry?

+1.0000E+02

The symmetry is set as 100%.