beautypg.com

Source[1]:marker:frequency – GW Instek AFG-3000 Series User Manual

Page 249

background image

REMOTE

INTERFACE

249

Example

OUTP1:TRIG?
1

The Trig out signal is enabled.

SOURce[1]:MARKer:FREQuency

Source Specific
Command

Description

Sets or queries the marker frequency. The default
marker frequency is 500 Hz. The marker frequency
is used to output a SYNC signal from the SYNC
terminal on the front panel. The SYNC signal goes
logically high at the start of each sweep and goes
low at the marker frequency.

Note

The marker frequency must be between the start
and stop frequencies. If the marker frequency is set
to a value that is out of the range, the marker
frequency will be set to the center frequency and a
“settings conflict” error will be generated.

Syntax

SOURce[1]:MARKer:FREQuency
{|MINimum|MAXimum}

Parameter

100 μHz ~ 80 MHz(3081)/
50MHz(3051)100 μHz ~ 1
MHz (Ramp)

Example

SOUR1:MARK:FREQ +1.0000E+03

Sets the marker frequency to 1 kHz.

Query Syntax

SOURce[1]:MARKer:FREQuency? [MINimum|
MAXimum]

Return Parameter

Returns the marker
frequency in Hz.

Example

SOUR1:MARK:FREQ? MAX
+1.0000E+03

Returns the marker frequency (1 kHz).