beautypg.com

Source[1]:frequency – GW Instek AFG-3000 Series User Manual

Page 212

background image

AFG-3000 Series User Manual

212

Sine Squ Tri Ramp Pulse Noise ARB

AM

     

FM

     

PWM       

FSK

     

SWEEP       

BRUST       

Syntax

SOURce[1]:FUNCtion {SINusoid|SQUare|RAMP|
PULSe|NOISe|TRIAngle|DC| USER}

Example

SOUR1:FUNC SIN

Sets the output as a sine function.

Query Syntax

SOURce[1]:FUNCtion?

Return Parameter SIN, SQU, RAMP, PULS,

NOIS, DC, TRI, USER

Returns the current output
type.

Example

SOUR1:FUNC?

SIN

Current output is sine.

SOURce[1]:FREQuency

Source Specific
Command

Description

Sets the output frequency for the
SOURce[1]:FUNCtion command. The query
command returns the current frequency setting.

Note

The maximum and minimum frequency depends
on the function mode.

Sine,

Square

1μHz~80MHz(3081)/
50MHz(3051)

Ramp, Triangle

1μHz~80MHz(3081)/
50MHz(3051)

Pulse

50μHz~50MHz

Noise, DC

Not applicable