Parameter

1μHz~100MHz

0~10V (50Ω)

0~5V (50Ω)

Example

SOUR1:APPL:USER

SOURce[1]:APPLy?

Source Specific
Command

Description

Outputs a string with the current settings.

Note

The string can be passed back appended to the
Apply Command.

Syntax

SOURce[1]:APPLy?

Return Parameter Function,

frequency,

amplitude, offset

Example

SOUR1:APPL?
SIN +5.0000000000000E+03,+3.0000E+00,-2.50E+00

Returns a string with the current function and