beautypg.com

GW Instek AFG-3000 Series User Manual

Page 285

background image

REMOTE

INTERFACE

285

-222 Data out of range;marker confined to sweep span; value clipped
to ...

Example: The marker frequency is set to a value
outside the start or stop frequencies. The marker
frequency is automatically adjusted to either the
start or stop frequency (whichever is closer to the set
value).

-222 Data out of range;FM deviation; value clipped to ...

Example: The frequency deviation is outside of
range. The deviation is automatically adjusted to an
upper or lower limit, depending on the frequency.

-222 Data out of range;trigger delay; value clipped to upper limit

Example: The trigger delay was set to a value out of
range. The trigger delay has been adjusted to the
maximum (85 seconds).

-222 Data out of range; trigger delay limited by length of burst; value
clipped to upper limit

Example: The trigger delay and the burst cycle time
combined must be less than the burst period.

-222 Data out of range;duty cycle; value clipped to ...

Example: The duty cycle is limited depending on the
frequency.
Duty Cycle

Frequency

50%

>

50MHz

40%~60%

25 MHz ~ 50MHz

20%~80%

< 25 MHz

-222 Data out of range; duty cycle limited by frequency; value clipped to
upper limit

Example: The duty cycle is limited depending on the
frequency. When the frequency is greater than 50
MHz, the duty cycle is automatically limited to 50%.