beautypg.com

Yokogawa Data Acquisition with PID Control CX2000 User Manual

Page 19

background image

3-3

M-4659

Configuring the DX1000/DX2000

1

2

3

4

5

6

7

8

Index

3.2

Setting and Checking the System Configuration

and Initializing Settup Data

Changing/Checking the System Configuration

You can create new hardware configuration files, or open existing configuration files
and then check the system configuration or change the configuration according to the
specifications of the connected DX1000/DX2000.
Normally, a system is set up according to the specifications of the DX1000/DX2000 to be
set up.

1.

Choose [System] - [System Configuration] from the menu bar.

The [System Configuration] dialog box opens.
Click the [DXAdvanced] tab.

2.

Change the various settings according to the DX1000/DX2000 that you will

connect to (blue and brown items are selected, gray items are cleared).
The settings in the Option group differ depending on the model and options of the

instrument.

For example, for the DX1000, or for the DX2000 with eight channels or fewer, the

external function item cannot be selected. If [Pulse] is selected (blue), the [Math]
and [Remote] items are disabled.

3.

After changing the configuration and clicking the [OK] button, the message,

“System configuration has been changed.

The input configuration and data will be initialized. Continue?” appears.

4.

Click the [OK] button to initialize the data.