beautypg.com

Teledyne LeCroy SierraFC M8-4 User Manual User Manual

Page 320

background image

Teledyne LeCroy

Scenario Batch Files

320

 

 

SierraFC M8‐4 Protocol Analyzer User Manual

Note:

You can use a Label and a Goto Label to make loops. First make the label, then make Goto Label. 

The Command Parameters window shows only enabled Labels.

Run

Runs the Scenario on hardware on specified ports. If you call this command for the first 
time and the Scenario was not assigned to the hardware and ports before, the Scenario is 
assigned to specified hardware and ports and then Scenario runs on the hardware.

Format

Run(Serial Number, Scenario Name, Responder Port)

Parameters

Serial Number: Serial number of hardware

Scenario Name: Name of Scenario

PortMap: Port number in port map

Example

Run (ox841200," Substitute address frame", 4)

Beep(800, 400)

Run (ox841200," CRC Inject _ Play CD", 8)

WaitForStop(0x63463, 1, 150)

Run (ox841200," Remove Send Cue Sheet", 2)

Goto Label6

Run (S/N: 12871, Port 1, DISCOVER)

Note:

If the selected ports are busy, Scenario cannot run, and the command will be skipped. The result 

will be written in the Log area.