Easy Mode (Pre‐Defined Setups)

166

 

 

SierraFC M8‐4 Protocol Analyzer User Manual

Each time a trigger condition occurs, the system records a new segment. You can use a 
Snapshot or Pattern trigger, but not Manual Trigger. As the same trigger automatically 
repeats, the system makes the number of segments that you entered.

Note:

If the size of a data packet exceeds the buffer memory allocation, the project runs, but no data 

capture occurs. You must increase buffer memory size to a value greater than the packet size.

Trigger Position

You can set the trigger position in the captured buffer as a percentage of the segment 
size. Trigger point of 0% means the trigger point will be on the first packet in the buffer.

To upload segments automatically for display as the system creates them, do not select 
the checkbox.This defaults to 1, which defines the amount of data to capture before and 
after the triggering Event. You can change this percentage by dragging the slider.

In certain cases, when one port is recording traffic and filling up the memory much faster 
than another port, you might see traffic appearing only on one port for a while, and the 
other port's traffic will only appear later. This occurs as a function of the trigger position, 
and is normal, expected behavior of the analyzer.

To upload segments manually in the Segment Manager, select the Use upload manager 
(no automatic upload)
 checkbox. To upload segments automatically for display as the 
system creates them, do not select the checkbox.

Auto Run

To repeat the current capture and trigger setup automatically, check the Auto Run 
checkbox and enter the number of times in the Number of Run text box. The capture and 
trigger repeat automatically for the specified number of times, and the results are saved 
in consecutively numbered Trace.scs files. Each one will use the same settings as 
specified, and will create sequentially named traces. This is identical to pressing the 
record button several times in a row. 

Training Signal Pack Mode

You can select the Training Signal Pack Mode option:

Unpacked

Packed

Trace File Name

Click the ellipses next to the Trace File Name text box (see 

Figure 2.127 on page 167

)and 

choose a file name and location for the results of your current project.