Set port alias, External trig setting, External trig setting” on – Teledyne LeCroy SierraFC M8-4 User Manual User Manual
Page 245

SierraFC M8‐4 Protocol Analyzer User Manual
245
Software Settings
Teledyne LeCroy
Set Port Alias
Port Alias allows you to assign a meaningful name to each port to assist in interpreting the
results displayed in the sample view.
To assign port names in an open sample view, select Configuration > Set Port Alias.
Figure 3.77: Assign Port Alias
Assign a meaningful name to each port for each unit in use and click OK. The assigned
names replace the port numbers in the sample view.
If you elect to save the capture sample file, the assigned port names are saved together
with the result, so that when you open the sample file later, the assigned names are
retained.
Set As Default
If you want to set these port aliases for sample files that will be captured later, you can set
them as default, and new samples will be opened by these default port aliases.
External Trig Setting
The External Trig Setting dialog displays the External Trig Out Setting and External Trig In
Setting as High Active, Low Active, or Toggle.
Figure 3.78: External Trigger Setting Dialog
To display the External Trig Setting dialog, select Configuration > External Trig Setting.