beautypg.com

Protocol errors, Trigger setup – Teledyne LeCroy SierraFC M8-4 User Manual User Manual

Page 145

background image

    

SierraFC M8‐4 Protocol Analyzer User Manual

145

Easy Mode (Pre‐Defined Setups)

 Teledyne   LeCroy

FC‐AE 1553

FC‐ASM

FC‐VI

FC‐AV Container

ARINC 818

Generic FC Feat

RNID Gen. Top. Dis. Page

Protocol Errors

Double‐click Protocol Errors to open the Add Protocol Error Pattern selection dialog.

Figure 2.114: Protocol Error Pattern Dialog

Check protocol error(s) and then click OK.

Note:

The Analyzer counts the errors in Frame base, while Infusion counts the errors in DWORD base 

hence, there is a difference in captured errors between the Analyzer and Infusion. The errors in 
Infusion are always higher.

Trigger Setup

The Trigger tab in the analysis project dialog allows you to specify when the analyzer 
completes a data capture. Three trigger modes are available: The default Snapshot, 
Manual Trigger, 
and Pattern/Event Trigger.