beautypg.com

Example 3: using timers – Teledyne LeCroy SierraFC M8-4 User Manual User Manual

Page 306

background image

Teledyne LeCroy

Scenario Examples

306

 

 

SierraFC M8‐4 Protocol Analyzer User Manual

Figure 4.29: Example 2: Complete Scenario of Insert DWORD in Advanced Mode

Example 3: Using Timers

This section gives you a sample describing the use of Timers. In this example the Global 
Rules portion of the Scenario waits for an Ordered Set, Frame Delimiters from P1/P3. 
Each time the device detects an Ordered Set, Frame Delimiters it injects an Invalid 10‐bit 
Code Error into the traffic stream. This state continues for a random period of time, not 
to exceed 1.790 seconds. After the time period has elapsed (i.e., the timer times out), the 
Scenario stops.

Although this example sets the timer for a random period, you also can set the timer for 
known values (2 ms., 5 mins., 1 hr., and so on).

1. Click the New Scenario button in the main library or one of the device libraries. In 

the Scenario Properties dialog, enter the Scenario name, description, and direction 
of traffic change.

2. As in previous examples, configure the first Event and its response in the Global 

Rules area. Choose Ordered Set, Frame Delimiters as the Event and Inject an Invalid 
10‐bit Code Error as the Action.

3. Click the prompt to add another event (keep in mind this is not a Combined Event).