beautypg.com

Position part – IAI America PSEL User Manual

Page 98

background image




88

Part 2 Programs


SEL language consists of a position part (position data = coordinates, etc.) and a command part
(application program).

2. Position

Part


As position data, coordinates, speeds, accelerations and decelerations are set and stored.






Position No.

Axis 1

Axis 2

Speed

Acceleration Deceleration

1

2

3




1498

1499

1500




*1 Varies depending on the actuator model.
*2 If speed, acceleration or deceleration is set in the position data, the setting will be given priority over

the corresponding data set in the application program. Leave the position data fields empty if you
wish to enable the corresponding data in the application program.

Priority Speed

Acceleration

(deceleration)

1

Value of position data set in operand 1

Value of position data set in operand 1

2

Value set by a VEL command

Value set by an ACC (DCL) command

3

All-axis parameter No. 11, “Default acceleration”
(All-axis parameter No. 12, “Default
deceleration”)

Values pertaining to a rotating axis are processed in degrees instead of millimeters.

If axis-specific parameter No. 1 (axis operation type) is set to “1” (rotational movement axis (angle
control)) for a given axis, all millimeter values pertaining to that axis (including parameters, etc.) will be
processed in degrees.

If the gear ratio parameters (axis-specific parameter Nos. 50 and 51) are set correctly, the angles
(deg) will represent those of the body of rotation at the end.

Example) Distance

1

mm

 1 deg

Speed

1

mm/sec

 1 deg/sec

Acceleration/deceleration 1 G = 9807 mm/sec

2

 9807 deg/sec

2

 2000000.000 mm

*1, 2
1 ~ 2000/mmsec

*2
Standard
0.3 G

*2
Standard
0.3 G