beautypg.com

Movements through positions – IAI America PSEL User Manual

Page 332

background image




322

Part 3 Positioner Mode

5.3 Movements

through

Positions

Timings of how the actuator moves through positions are illustrated below.




























Timing Chart of Movement through Positions (Standard Positioner Mode)

T

1

: At least 6 msec


Operate the actuator to move through positions by following the procedure explained below.
* Confirm beforehand that the positioning complete output signal, home-return complete output signal

and servo-ON status output signal are all ON.
[1] Change the previous product/position number inputs to different product/position numbers.
[2] Turn ON the start input signal.
[3] Confirm that the positioning complete output signal is OFF.
[4] Turn OFF the start input signal.
[5] Confirm that the positioning complete output signal is ON.

Repeat steps [1] through [5] sequentially.

* Pause and *cancellation inputs are contact-B input signals (always ON), so keep these signals ON

while the actuator are moving through the specified positions.

Input

Output

000: Start


002: Home return

007 ~ 019: Position input


300: Alarm


301: Ready

302: Positioning
complete


303: Home return
complete

304: Servo ON status

[3]

[2]

[4] [7]

[9]

[10]

[8]

[5]

[6]