beautypg.com

IAI America PSEL User Manual

Page 55

background image




45

Part 1 Installation


(2) Output

part

External Output Specifications (PNP Specification)

Item

Specification

Load voltage

24 VDC

Maximum load current 100 mA per point, 400 mA per 8 ports Note)

Leakage current

0.1 mA max. per point

TD62784 (or equivalent)

Isolation method

Photocoupler isolation

External devices

[1] Miniature

relay

[2] Sequencer input unit

Note) 400 mA is the maximum total load current of output port Nos. 300 to 307.


[Output circuit]



















* P24: I/O interface pin No. 1A

* N: I/O interface pin No. 17B

Caution

In the event that the load is short-circuited or a current exceeding the maximum load
current is input, the overcurrent protection circuit will be actuated to cut off the circuit.
However, give due consideration to the circuit connection layout to prevent short-circuit
or overcurrent.

Internal cir

c

uit

10

N

P24

Surge absorber

Output terminal

Load

External power supply
24 VDC

10%

+

-