(In the panel window, the three digits after “E” indicate an error number.)
Error No.
Error name
Description, action, etc.
D75
Fieldbus parameter error
The field bus parameter is abnormal. Check I/O Parameter Nos. 226, 227, etc.
D76
Fieldbus module non-installation error
No fieldbus module is installed.
E01
DMA address error
DMA transfer error
E02
SCIF send-buffer overflow error
The SCIF send buffer overflowed.
E03
SCI send-buffer overflow error
The SCI send buffer overflowed.
E04
SCIF receive-buffer overflow error
The SCIF receive buffer overflowed. Excessive data was received from outside.
E05
SCI receive-buffer overflow error
The SCI receive buffer overflowed. Excessive data was received from the slave.
E06
Receive timeout error (Slave communication)
Response from the slave cannot be recognized.
E07
SCI overrun error (Slave communication)
Communication failure. Check for noise, circuit failure and slave card.
E08
SCI framing error (Slave communication)
Communication failure. Check for noise, shorting, circuit failure and slave card.
E09
SCI parity error (Slave communication)
Communication failure. Check for noise, shorting, circuit failure and slave card.
E0A
SCI CRC error (Slave communication)
The CRC in the message is invalid.
E10
SCIF communication mode error
The communication mode is invalid.
E11
SCI communication mode error
The communication mode is invalid.
E14
SCI receive-data-register full wait timeout error
Communication failure. Check for noise, shorting, circuit failure and slave card.
E15
SCI overrun error
Communication failure. Check for noise, shorting, circuit failure and slave card.
E16
Program end confirmation timeout error
The program cannot be ended.
E17
I/O-processing-program start logic error
The I/O-processing-program start logic is invalid.
E18
Task ID error
The task ID is invalid.
E19
WAIT factor error
The WAIT factor is invalid.
E1A
WAIT logic error
The WAIT logic is invalid.
E1B
Point-data valid address error
Point-data valid address is not set.
E1C
Source data error
The source data is invalid.
E1D
Unaffected output number error
The unaffected output number is invalid. A value other than an output port
number (“0” is acceptable) may be input in I/O parameter Nos. 70 to 73.
E1E
Zone parameter error
A value other than an output port/global flag number (“0” is acceptable) or
duplicate numbers may be input in axis-specific parameter Nos. 88, 91, 94 and
97, or the output number specified as system output in the I/O parameter for
output function selection may be duplicated, among other reasons.