415 appendix axis-specific parameters – IAI America PSEL User Manual
Page 425
415
Appendix
Axis-Specific Parameters
No Parameter
name
Default value
(Reference)
Input range
Unit
Remarks
86 Zone
1
MAX
0
-99999999
~ 99999999
0.001 mm Zone output ON if MAX > MIN or MAX
Current position MIN
Zone output ON if MAX < MIN, Current position
MAX, or MIN
Current position
Zone output ignored if MAX = MIN
(The “MAX < MIN” setting is effective in main application
version 0.21 or later.)
* Must be inside the range for at least 3 msec.
87 Zone
1
MIN
0
-99999999
~ 99999999
0.001 mm Zone output ON if MAX > MIN or MAX
Current position MIN
Zone output ON if MAX < MIN, Current position
MAX, or MIN
Current position
Zone output ignored if MAX = MIN
(The “MAX < MIN” setting is effective in main application
version 0.21 or later.)
* Must be inside the range for at least 3 msec.
88
Zone 1 output number
0
0 ~ 899
Physical output port or global flag
(Output is invalid if “0” is input; multiple specification is invalid)
89 Zone
2
MAX
0
-99999999
~ 99999999
0.001 mm Zone output ON if MAX > MIN or MAX
Current position MIN
Zone output ON if MAX < MIN, Current position
MAX, or MIN
Current position
Zone output ignored if MAX = MIN
(The “MAX < MIN” setting is effective in main application
version 0.21 or later.)
* Must be inside the range for at least 3 msec.
90 Zone
2
MIN
0
-99999999
~ 99999999
0.001 mm Zone output ON if MAX > MIN or MAX
Current position MIN
Zone output ON if MAX < MIN, Current position
MAX, or MIN
Current position
Zone output ignored if MAX = MIN
(The “MAX < MIN” setting is effective in main application
version 0.21 or later.)
* Must be inside the range for at least 3 msec.
91
Zone 2 output number
0
0 ~ 899
Physical output port or global flag
(Output is invalid if “0” is input; multiple specification is invalid)
92 Zone
3
MAX
0
-99999999
~ 99999999
0.001 mm Zone output ON if MAX > MIN or MAX
Current position MIN
Zone output ON if MAX < MIN, Current position
MAX, or MIN
Current position
Zone output ignored if MAX = MIN
(The “MAX < MIN” setting is effective in main application
version 0.21 or later.)
* Must be inside the range for at least 3 msec.
93 Zone
3
MIN
0
-99999999
~ 99999999
0.001 mm Zone output ON if MAX > MIN or MAX
Current position MIN
Zone output ON if MAX < MIN, Current position
MAX, or MIN
Current position
Zone output ignored if MAX = MIN
(The “MAX < MIN” setting is effective in main application
version 0.21 or later.)
* Must be inside the range for at least 3 msec.
94
Zone 3 output number
0
0 ~ 899
Physical output port or global flag
(Output is invalid if “0” is input; multiple specification is invalid)