beautypg.com

IAI America PSEL User Manual

Page 459

background image

449

Appen

dix

(In the panel window, the three digits after “E” indicate an error number.)

Error No.

Error name

Description, action, etc.

C72

Overrun error

The overrun sensor was actuated.

C73

Target-locus soft limit over error

The target position or movement locus exceeds a soft limit.
* In the case of a SCARA specification, position data may not exist for the

applicable axis.

C74

Actual-position soft limit over error

The actual position exceeds a soft limit by the “soft limit/actual position margin” or
more.

C75

Motion-data-packet generation logic error

The motion-data-packet generation logic is invalid.

C76

Movement-point count over error

Too many packets are generated simultaneously.

C77

Handling-packet overflow error

The servo handling packets overflowed.

C78

Motion-data-packet overflow error

The servo motion data packets overflowed.

C79

Pole sense operation error

Operation is disabled in the pole sense mode.

C7A

Servo unsupported function error

An attempt was made to use an unsupported function.

C7B

Odd-pulse slide error

Internal servo calculation error

C7C

Odd-pulse processing logic error

Internal servo calculation error

C7D

Packet pulse shortage error

Internal servo calculation error

C7E

Quadratic equation solution error

An error was detected while calculating a quadratic equation solution.

C7F

No valid specified axis error

No valid axes are specified.

C80

Servo-packet calculation logic error

Internal servo calculation error
If the controller is of absolute encoder specification and the system has just been
moved or “Error No. C74, Actual-position soft limit over error” has also generated,
the controller may be experiencing a servo-packet calculation overflow caused by
abnormal current position resulting from an unsuccessful absolute reset. Perform an
absolute reset again by following the operation manual.
(Simply selecting “Encoder error reset” on the absolute reset screen will not allow
the controller to recognize the correct position. Always perform an absolute reset by
strictly following the specified procedure.)

C81

Operation-amount logic during servo ON

Servo processing logic error

C82

Servo direct command type error

Servo processing logic error

C83

Servo calculation method type error

The servo calculation method type is invalid.

C84

In-use axis servo OFF error

The servo of an axis currently in use (being processed) was turned off.

C85

Non-installed driver error

Driver is not installed for the applicable axis.

C86

Driver servo ready OFF error

The ready signal for the driver of the applicable axis is OFF.

C87

SEL unsupported function error

An attempt was made to use a function not supported by SEL.

C88

Speed specification error

The specified speed is invalid.

C89 Acceleration/deceleration

specification

error

The specified acceleration/deceleration is invalid.