IAI America PSEL User Manual
Page 459
![background image](/manuals/350325/459/background.png)
449
Appen
dix
(In the panel window, the three digits after “E” indicate an error number.)
Error No.
Error name
Description, action, etc.
C72
Overrun error
The overrun sensor was actuated.
C73
Target-locus soft limit over error
The target position or movement locus exceeds a soft limit.
* In the case of a SCARA specification, position data may not exist for the
applicable axis.
C74
Actual-position soft limit over error
The actual position exceeds a soft limit by the “soft limit/actual position margin” or
more.
C75
Motion-data-packet generation logic error
The motion-data-packet generation logic is invalid.
C76
Movement-point count over error
Too many packets are generated simultaneously.
C77
Handling-packet overflow error
The servo handling packets overflowed.
C78
Motion-data-packet overflow error
The servo motion data packets overflowed.
C79
Pole sense operation error
Operation is disabled in the pole sense mode.
C7A
Servo unsupported function error
An attempt was made to use an unsupported function.
C7B
Odd-pulse slide error
Internal servo calculation error
C7C
Odd-pulse processing logic error
Internal servo calculation error
C7D
Packet pulse shortage error
Internal servo calculation error
C7E
Quadratic equation solution error
An error was detected while calculating a quadratic equation solution.
C7F
No valid specified axis error
No valid axes are specified.
C80
Servo-packet calculation logic error
Internal servo calculation error
If the controller is of absolute encoder specification and the system has just been
moved or “Error No. C74, Actual-position soft limit over error” has also generated,
the controller may be experiencing a servo-packet calculation overflow caused by
abnormal current position resulting from an unsuccessful absolute reset. Perform an
absolute reset again by following the operation manual.
(Simply selecting “Encoder error reset” on the absolute reset screen will not allow
the controller to recognize the correct position. Always perform an absolute reset by
strictly following the specified procedure.)
C81
Operation-amount logic during servo ON
Servo processing logic error
C82
Servo direct command type error
Servo processing logic error
C83
Servo calculation method type error
The servo calculation method type is invalid.
C84
In-use axis servo OFF error
The servo of an axis currently in use (being processed) was turned off.
C85
Non-installed driver error
Driver is not installed for the applicable axis.
C86
Driver servo ready OFF error
The ready signal for the driver of the applicable axis is OFF.
C87
SEL unsupported function error
An attempt was made to use a function not supported by SEL.
C88
Speed specification error
The specified speed is invalid.
C89 Acceleration/deceleration
specification
error
The specified acceleration/deceleration is invalid.