Chapter 5 Maintenance


 Routine maintenance and inspection are necessary so that the system will operate properly at all

times. Be sure to turn off the power before performing maintenance or inspection.

 The standard inspection interval is six months to one year. If the environment warrants, however, the

interval should be shortened.

1. Inspection

points

 Check to see if the supply voltage to the controller is inside the specified range.

 Inspect the ventilation holes in the controller and remove dirt, dust and other foreign attachments,

if any.

 Inspect the controller cables (controller  actuator) and check for any loose screws or cable

disconnection.

 Check the controller mounting screws, etc., for looseness.

 Inspect each cable (axis link cable, general-purpose I/O cable, system I/O cable, power cable) for

loose connection, disconnection, play, etc.

2. Spare consumable parts


Without spare parts, a failed controller cannot be repaired even when the problem is identified quickly. We
recommend that you keep the following consumable parts as spares:

Consumable parts
 Cables

 System-memory backup battery: (optional): AB-5 by IAI -- Must be replaced after approx. 5 years*

*: The actual replacement timing will vary depending on the use condition. For details, refer to

 Battery Backup Function” in Appendix.



When the battery voltage drops, an applicable error code will be displayed on the panel window.

Error Codes Indicating Low Battery Voltage

System-memory backup battery

A01 or A02