(In the panel window, the three digits after “E” indicate an error number.)

Error No.

Error name

Description, action, etc.

A51

Operation-pause reset request refusal error The

all-operation-pause factor (drive-source cutoff, operation-pause signal, deadman

switch, safety gate, emergency stop, etc.) has not been removed.

A53

Refusal error due to servo ON

A processing not permitted during servo ON was attempted.

A54

Refusal error due to unsupported function

The function is not supported.

A55

Refusal error due to exclusive manufacturer function

A processing not opened to users other than the manufacturer was attempted.

A56

Refusal error due to invalid data

The data is invalid.

A57

Program start duplication error

An attempt was made to start a program currently running.

A58

BCD error warning

The BCD value being read may be invalid, or the value being written (variable 99)
may be a negative value, among other reasons.

A59

IN/OUT command port flag error warning

The number of I/O ports (flags) may have exceeded 32, among other reasons. Check
the I/O port (flag) specifications.

A5B

Character-string

 value conversion error warning

The specified number of converting characters is invalid or characters that cannot be
converted to value are included.

A5C

Copying-character count error warning with SCPY command

The specified number of copying characters is invalid.

A5D

SCIF open error in non-AUTO mode

The channel was opened in a non-AUTO mode. In the MANU mode, the PC/TP
connection must be forcibly disconnected before opening the serial channel opened
to the user. Exercise caution.

A5E

I/O-port/flag count specification error

The specified number of I/O ports/flags is invalid.

A5F

Fieldbus error (LERROR-ON)

A LERROR-ON was detected.

A60

Fieldbus error (LERROR-BLINK)

A LERROR-BLINK was detected.

A61

Fieldbus error (HERROR-ON)

A HERROR-ON was detected.

A62

Fieldbus error (HERROR-BLINK)

A HERROR-BLINK was detected.

A63

Fieldbus not ready

Fieldbus ready cannot be confirmed.

A69

Data change refusal error during operation

An attempt was made to change data whose change is prohibited during operation
(program is running, servo is in use, etc.).

A6A

Software reset refusal error during write

Software reset is prohibited while data is being written to the flash ROM or slave
parameters are being written.

A6B

Fieldbus error (FBRS link error)

A FBRS link error was detected.

A6C

PC/TP start command refusal error in AUTO mode

Starting from the PC software/TP connector is prohibited in the AUTO mode.

A6D

P0/P3/FROM-area direct write prohibition error

Direct write to the P0/P3/FROM areas is prohibited.

A6E

Refusal error during write

A processing not permitted while data is being written to the flash ROM or slave
parameters are being written was attempted.

A6F

Driver monitor type mismatch error

The monitor type supported by the standard DIO board or based on the capacity of
FROM on the main CPU board does not match the monitor type on the PC software
side (selected on the monitor screen).