424 appendix other parameters – IAI America PSEL User Manual
Page 434
![background image](/manuals/350325/434/background.png)
424
Appendix
Other Parameters
No. Parameter
name
Default value
(Reference)
Input range
Unit
Remarks
36 PC/TP
data
protect
setting (Program)
0H 0H
~
FFFFFFFFH
Bits 0 to 3:
Protect type (0: Read/write, 1: Read only, 2:
No read/write)
Bits 4 to 7:
Protect release method (0: Special operation)
Bits 8 to 11:
Protect range maximum number (1’s place,
BCD)
Bits 12 to 15:
Protect range maximum number (10’s place,
BCD)
Bits 16 to 19:
Protect range minimum number (1’s place,
BCD)
Bits 20 to 23:
Protect range minimum number (10’s place,
BCD)
* Referenced by the PC/TP
37 PC/TP
data
protect
setting (Position)
0H 0H
~
FFFFFFFFH
Bits 0 to 3:
Protect type (0: Read/write, 1: Read only, 2:
No read/write)
Bits 4 to 7:
Protect release method (0: Special
operation)
Bits 8 to 11:
Protect range maximum number (10’s place,
BCD)
Bits 12 to 15:
Protect range maximum number (100’s
place, BCD)
Bits 16 to 19:
Protect range maximum number (1000’s
place, BCD)
Bits 20 to 23:
Protect range minimum number (10’s place,
BCD)
Bits 24 to 27:
Protect range minimum number (100’s
place, BCD)
Bits 28 to 31:
Protect range minimum number (1000’s
place, BCD)
* The value in the 1’s place is considered “0” for both the
protect range maximum/minimum numbers.
* Referenced by the PC/TP
38 PC/TP
data
protect
setting (Symbol,
parameter)
0H 0H
~
FFFFFFFFH
Bits 0 to 3:
Protect type (Parameter) (0: Read/write, 1:
Read only, 2: No read/write)
Bits 4 to 7:
Protect release method (Parameter) (0:
Special operation)
Bits 8 to 11:
Protect type (Symbol) (0: Read/write, 1: Read
only, 2: No read/write)
Bits 12 to 15:
Protect release method (Symbol) (0: Special
operation)
* Referenced by the PC/TP
39
(For future expansion)
0H
0H ~
FFFFFFFFH