beautypg.com

424 appendix other parameters – IAI America PSEL User Manual

Page 434

background image




424

Appendix


Other Parameters

No. Parameter

name

Default value

(Reference)

Input range

Unit

Remarks

36 PC/TP

data

protect

setting (Program)

0H 0H

~

FFFFFFFFH

Bits 0 to 3:

Protect type (0: Read/write, 1: Read only, 2:
No read/write)

Bits 4 to 7:

Protect release method (0: Special operation)

Bits 8 to 11:

Protect range maximum number (1’s place,
BCD)

Bits 12 to 15:

Protect range maximum number (10’s place,
BCD)

Bits 16 to 19:

Protect range minimum number (1’s place,
BCD)

Bits 20 to 23:

Protect range minimum number (10’s place,
BCD)

* Referenced by the PC/TP

37 PC/TP

data

protect

setting (Position)

0H 0H

~

FFFFFFFFH

Bits 0 to 3:

Protect type (0: Read/write, 1: Read only, 2:
No read/write)

Bits 4 to 7:

Protect release method (0: Special
operation)

Bits 8 to 11:

Protect range maximum number (10’s place,
BCD)

Bits 12 to 15:

Protect range maximum number (100’s
place, BCD)

Bits 16 to 19:

Protect range maximum number (1000’s
place, BCD)

Bits 20 to 23:

Protect range minimum number (10’s place,
BCD)

Bits 24 to 27:

Protect range minimum number (100’s
place, BCD)

Bits 28 to 31:

Protect range minimum number (1000’s
place, BCD)

* The value in the 1’s place is considered “0” for both the

protect range maximum/minimum numbers.

* Referenced by the PC/TP

38 PC/TP

data

protect

setting (Symbol,
parameter)

0H 0H

~

FFFFFFFFH

Bits 0 to 3:

Protect type (Parameter) (0: Read/write, 1:
Read only, 2: No read/write)

Bits 4 to 7:

Protect release method (Parameter) (0:
Special operation)

Bits 8 to 11:

Protect type (Symbol) (0: Read/write, 1: Read
only, 2: No read/write)

Bits 12 to 15:

Protect release method (Symbol) (0: Special
operation)

* Referenced by the PC/TP

39

(For future expansion)

0H

0H ~

FFFFFFFFH