IAI America PSEL User Manual
Page 461

451
Appen
dix
(In the panel window, the three digits after “E” indicate an error number.)
Error No.
Error name
Description, action, etc.
CA6
Palletizing number error
The specified palletizing number is invalid.
CA7
Setting error of even-numbered row count for palletizing zigzag
The set even-numbered row count for palletizing zigzag is invalid.
CA8
Setting error of palletizing pitches
The set palletizing pitches are abnormal.
CA9
Setting error of placement points in palletizing-axis directions
The set X/Y-axis direction counts for palletizing are invalid.
CAA
Palletizing PASE/PAPS non-declaration error
Neither PASE nor PAPS palletizing-setting command is set. Set either command.
CAB
Palletizing position number error
The specified palletizing position number is invalid.
CAC
Palletizing position number setting over
The specified palletizing position number exceeds the position number range
calculated for the current palletizing setting.
CAD
Palletizing PX/PY/PZ-axis duplication error
Any two of the specified PX, PY and PZ-axes for palletizing are the same axis.
CAE
Insufficient valid axes for palletizing 3-point teaching data
There are not enough valid axes in the point data for palletizing 3-point teaching.
Axes to comprise the palletizing PX/PY planes cannot be specified.
CAF
Excessive valid axes for palletizing 3-point teaching data
There are too many valid axes in the point data for palletizing 3-point teaching.
Axes to comprise the palletizing PX/PY planes cannot be specified.
CB0
Mismatched valid axes for palletizing 3-point teaching data
The valid axis pattern in the point data for palletizing 3-point teaching does not
match.
CB1
Offset setting error at palletizing 3-point teaching
Zigzag offset (not zero) cannot be set in palletizing 3-point teaching, if the
reference point is the same as the end point of the PX-axis.
CB2
BGPA/EDPA pair-end mismatch error
The BGPA/EDPA syntax is invalid. EDPA was declared before BGPA, or another
BGPA was declared after BGPA without first declaring EDPA.
CB4
Arch-motion Z-axis non-declaration error
Z-axis has not been declared by PCHZ or ACHZ.
CB5
BGPA non-declaration error during palletizing setting
Palletizing setting cannot be performed without first declaring BGPA. Declare
BGPA.
CB6
Palletizing point error
The palletizing points are invalid (non-Z-axis components for arch-motion
movement are absent, etc.).
CB7
Arch-trigger non-declaration error
Declare arch triggers using PTRG or ATRG.
CB8
No 3-point teaching setting error at palletizing angle acquisition
The palletizing angle cannot be acquired until setting by palletizing 3-point
teaching is complete.
CB9
PX/PY-axis indeterminable error at palletizing angle acquisition
Angle cannot be calculated because there are too many valid axes in the 3-point
teaching data and thus PX/PY-axes cannot be specified.
CBA Reference-axis/PY/PY-axis
mismatch error at palletizing angle
acquisition
Angle cannot be calculated because the reference axis for angle calculation is
neither of the axes comprising the PX/PY-axes as set by 3-point teaching.
CBB Reference-point/PX-axis
end-point duplication error at palletizing
angle acquisition
Angle cannot be calculated because the reference point of 3-point teaching is the
same as the PX-axis end-point data other than the PZ-axis component and thus
arc tangent cannot be calculated.
CBC
Palletizing motion calculation error
Trapezoid control calculation error for palletizing motion
CBD
MOD command divisor 0 error
“0” was specified as the divisor in the MOD command.