Part 2 Programs
If the valid axis pattern does not match the point data for 3-point teaching or 4-point teaching, an
error “CB0, Mismatched valid axes for palletizing 3-point teaching data” will generate. If a PAPS
command is executed after specifying the applicable axes using a GRP command, only the point
data corresponding to the specified axes, among all axes whose point data is valid, will be used as
palletizing point data. Executing a GRP command thereafter with a different setting will have no
effect.
If there are not enough valid axes, an error “CAE, Insufficient valid axes for palletizing 3-point
teaching data” will generate.
This command cannot be used with a PASE (set palletizing axes) command. Whichever was set later
will be given priority. (A single PAPS command can substitute a set of PASE, PAPT and PAST
commands.)
If this command is executed before BGPA is declared (= while palletizing setting is not enabled), an
error, “CB5, BGPA not declared at palletizing setting” will generate.
If the output field is specified, the output will turn ON after this command is executed.