416

Appendix


Axis-Specific Parameters

No Parameter

name

Default value

(Reference)

Input range

Unit

Remarks

95 Zone

4

MAX

0

-99999999

~ 99999999

0.001 mm Zone output ON if MAX > MIN or MAX

 Current position  MIN

Zone output ON if MAX < MIN, Current position

 MAX, or MIN

 Current position
Zone output ignored if MAX = MIN
(The “MAX < MIN” setting is effective in main application
version 0.21 or later.)
* Must be inside the range for at least 3 msec.

96 Zone

4

MIN

0

-99999999

~ 99999999

0.001 mm Zone output ON if MAX > MIN or MAX

 Current position  MIN

Zone output ON if MAX < MIN, Current position

 MAX, or MIN

 Current position
Zone output ignored if MAX = MIN
(The “MAX < MIN” setting is effective in main application
version 0.21 or later.)
* Must be inside the range for at least 3 msec.

97

Zone 4 output number

0

0 ~ 899

Physical output port or global flag
(Output is invalid if “0” is input; multiple specification is invalid)

98 For future expansion

4

Reference

only

99 For

future

expansion

2

Reference

only

100

~

118

(For expansion)

0

~

119 FSG

0

0

~

100

120 FFF

10

0 ~ 100

* Change is prohibited unless instructed by the manufacturer.

121

~

170

(For expansion)

0

~

171

0

~

172

0

~

173

0

~

174

0

~

175

0

~

176

0

~

~

200

(For expansion)

0

~