423 appendix other parameters – IAI America PSEL User Manual
Page 433
![background image](/manuals/350325/433/background.png)
423
Appendix
Other Parameters
No. Parameter
name
Default value
(Reference)
Input range
Unit
Remarks
12 Automatic
operation
recognition type
0
0 ~ 3
0: Program is running AND all-operation-cancellation factor
is not present
1: [Program is running OR in AUTO mode] AND
all-operation-cancellation factor is not present
13 ~
19
(For expansion)
0
20 System-memory
backup
battery installation
function type
0
0 ~ 2
0: Not installed (SEL global data/error lists cannot be
recovered from the flash ROM)
1: Not installed (SEL global data/error lists can be
recovered from the flash ROM)
2: Installed
* When the power is turned on without battery installed,
point data can be copied from the flash ROM. * Use of
setting “1” will be prohibited for the time being due to
limitations. * When point data is lost due to a battery
error, the point data valid before the flash ROM was
written can be restored
Input “0” (not installed) and
transfer the setting to the controller, and then perform
a software reset without writing the flash ROM. The
point data last written to the flash ROM will be
restored. Thereafter, reset this parameter to the
original value. (No remedy is available for recovery of
SEL global data/error lists.)
21
Manual mode type
0
0 ~ 5
0: Always enable edit and SIO/PIO start (Initial condition
after connection = With safety speed)
1: Select edit and start (with password) (EU, etc.)
2: Always enable edit and SIO/PIO start (Initial condition
after connection = Without safety speed (cancellation))
* Referenced by the PC/TP.
22
Control use region
0
0 ~ 99
0: J, 1: E, 2: EU
23
PSIZ command function
type
0
0 ~ 5
0: Maximum number of point data areas
1: Number of point data used
24 Local
variable
number
for storing SEL
communication
command return code
99 1
~
99
1001 ~ 1099
25
Operation mode type
0
0 ~ 16
0: Program mode
1 to 16: Positioner mode
26 ~
29
(For expansion)
0
30
Option Password 00
0H
0H ~
FFFFFFFFH
HOME command option (Change prohibited)
* Change is prohibited unless instructed by the
manufacturer.
31
Option Password 01
0H
0H ~
FFFFFFFFH
Reserved (Change prohibited)
* Change is prohibited unless instructed by the
manufacturer.
32
Option Password 02
0H
0H ~
FFFFFFFFH
Reserved (Change prohibited)
* Change is prohibited unless instructed by the
manufacturer.
33 ~
35
(For expansion)
0
0H ~
FFFFFFFFH