Axis-specific parameters, 412 appendix – IAI America PSEL User Manual
Page 422
![background image](/manuals/350325/422/background.png)
412
Appendix
3. Axis-Specific
Parameters
No Parameter
name
Default value
(Reference)
Input range
Unit
Remarks
~
1
Axis operation type
0
0 ~ 1
0: Linear movement axis, 1: Rotational movement axis
(Angle control)
2 ~
5
(For expansion)
0
~
6 Coordinate/physical-operatio
n direction selection
1 0
~
1
0: Motor CCW
Positive direction on the coordinate
system
1: Motor CCW
Negative direction on the coordinate
system
7
Soft limit +
50000
-99999999 ~
99999999
0.001 mm
Fixed to 359.999 degrees internally in the index mode.
Invalid in the infinite-stroke mode.
8
Soft limit –
0
-99999999 ~
99999999
0.001 mm
Fixed to 0 degree internally in the index mode. Invalid in
the infinite-stroke mode.
9 Soft-limit
actual
position
margin
2000
0 ~ 9999
0.001 mm
Actual position margin in the positioning boundary
critical zone in the infinite-stroke mode
10 Home-return method
0
0 ~ 5
0: Z-phase search after end search (Offset move after
end search in the case of an actuator without Z-phase)
1: Current position 0 home (This parameter can be
specified only with an incremental encoder. Pay
attention to contact.)
2: Current position = Preset home
(This parameter can be specified only with an
incremental encoder. Pay attention to contact.)
11 Home-return
end-search
direction selection
0
0 ~ 1
0: Negative end of the coordinate system
1: Positive end of the coordinate system
12 Home preset value
0
-99999999 ~
99999999
0.001 mm
(Refer to axis-specific parameter No. 76)
13 SIO/PIO home-return order
0
0 ~ 16
Executed from the smallest one.
14 Home-sensor input polarity
0
0 ~ 2
0: Do not use, 1: Contact a, 2: Contact b
15 For
future
expansion
0
Reference
only
16 For
future
expansion
0
Reference
only
17 Initial home-sensor pull-out
speed at home return
10 1
~
100
mm/sec
18 For
future
expansion
100
Reference
only
19 End search speed at home
return
20 1
~
100
mm/sec
20 Z-phase search speed at
home return
3
1 ~ 10
mm/sec
Exercise caution, since limitations apply depending on
the read/encoder pulse count.
21 Offset travel distance at
home return
1000 -99999999
~
99999999
0.001 mm
Offset travel distance from the ideal Z-phase position
(Positive value = Applied in the direction of moving away
from the end) (Refer to axis-specific parameter No. 76)
* Note on absolute encoders
When a value near an integer multiple of the Z-phase
distance (including an offset travel distance of 0) is set
in this parameter, the servo will lock above Z-phase
upon absolute reset. As a result, the coordinates may
shift by the pulses corresponding to the Z-phase
distance. Therefore, never set a value near an integer
multiple of the Z-phase distance.
(Provide a sufficient margin with respect to the servo
amplitude.)
22 Allowable Z-phase position
error check value at home
return
200
0 ~ 99999999
0.001 mm
Minimum allowable distance between the end
(mechanical or LS) and Z-phase in a rotary encoder
specification. Z-phase search limit in a linear encoder
specification.
23 Z-phase count per encoder
revolution
1
1 ~ 8
Only “1” can be set, in the case of an absolute encoder.
Invalid in the case of a linear encoder.
24 Push stop check time at
home return
700
1 ~ 5000
msec
Used to confirm push action during home return.
25 Push stop check time at
positioning
500
1 ~ 5000
msec
Used to confirm push action during PUSH command
operation.