beautypg.com

3 all line profile, 2 port config – Planet Technology IP DSLAM IDL-4801 User Manual

Page 67

background image

IP DSLAM

67

Field

Definition

Loss of frame within 15 minutes

The threshold of the number of “Loss of Frame Seconds”
within 15 minutes performance data collection period.

Loss of signal within 15 minutes

The threshold of the number of “Loss of Signal Seconds”
within 15 minutes performance data collection period.

Loss of link within 15 minutes

The threshold of the number of “Loss of Link Seconds”
within 15 minutes performance data collection period.
(But only ATU-C side)

Loss of power within 15 minutes

The threshold of the number of “Loss of Power Seconds”
within 15 minutes performance data collection period.

Errored seconds

The threshold of the number of “Errored Seconds” within
15 minutes performance data collection period.

a. To create a new alarm profile, click the DSL Name drop-down list and then

select the blank.

b. After that, the fields become enable. Input the values in those fields and then

name the new alarm profile.

c. Click on

to submit or click on

to delete a alarm profile.

3.8.1.3 All Line Profile

Display all the Line Profile Configuration.

3.8.2 Port Config

Allow users to configure port configuration. Double Click on “Port Config” from the

Function List Window. The Port Configuration window appears.