beautypg.com

Planet Technology IP DSLAM IDL-4801 User Manual

Page 606

background image

IDL series User Guide

606

- Crash in CP self processing

- DP Init Failure

- CP crashed after DP Init

- DP crashed after DP Init

- DP internal Failure

- System in Loop

- Crash in DP Processing

SystemUpTime

This specifies the system up time in:

Days : Hours : Minutes : Seconds

PSR Reg

This specifies the value of the processor state register at the

time of the crash.

Wim Reg

The window invalid mask register.

PC

This specifies the value of the program counter at the time of

the crash.

nPC

This specifies the value of the next program counter at the

time of the crash.

Y Reg MSW

This specifies the value of MSW of the Y Register at the time

of the crash.

Y Reg LSW

This specifies the value of LSW of the Y Register at the time of

the crash.

Trap Num

This specifies the number of traps that caused the crash.

Trap Base Reg

This specifies the value of the Trap Base register at the time of

the crash.

Fault Status Reg

This specifies the value of the Fault Status Register at the time

of the crash.

Double Fault Reg

This specifies the value of the Double Fault Register at the

time of the crash.

IER

This specifies the value of the Implementation Extension

Register at the time of the crash.

Alternate Window - Reg#

Local

For crashes involving Alternate Windows, this capture

specifies all local register for Alternate Windows # 24 to 31

(0x1f to 0x18).

Alternate Window - Reg#

In

For crashes involving Alternate Windows, this capture

specifies all input register for Alternate Windows # 24 to

31(0x1f to 0x18).

Standard Window Dump

- Registers - Global

The Sparclet Global register.

Standard Window Dump

- Registers - Out

The output registers of the specified Sparclet Window.

Standard Window Dump The local registers of the specified Sparclet Window.