table) has been reached/exceeded for the SHDSL segment endpoint.
Reached/exceeded is determined by comparing the endpoint's CRC
anomalies in the current 15-minute interval (as set in SHDSL End Point Curr
Table) with the specified threshold.
SHDSL Loss of Sync Word Seconds 15-Minute Threshold hit: This
notification indicates that the Loss of Sync Word (LOSW) seconds threshold
(as set in SHDL End point alarm conf profile table) has been
reached/exceeded for the SHDSL segment endpoint. Reached/exceeded is
determined by comparing the endpoint's LOSW seconds in the current
15-minute interval (as set in SHDSL End Point Curr Table) with the specified
threshold.
SHDSL Unavailable Seconds 15-Minute Threshold hit: This trap indicates
that 15-minuteinterval threshold for SHDSL Unavailable Secondshas reached.
SHDSL Invalid number of Repeaters detected: This trap indicates the
number of Invalid repeaters detected.
SHDSL Loopback Failure detected:This trap indicates that loop back failure
has been detected.
SHDSL Power Backoff Setting changed: This trap specifies that Operational
state of VDSL line has changed.
SHDSL STU-C Init Fail: This notification indicates that STUC failure during
initialization due to peer STU not able to support requested configuration
SHDSL Local Power Loss: This trap specifies that local power loss of SHDSL
Change of OP state of SHDSL line: This trap specifies change of Operational
state of VDSL line.
SHDSL Framer OH and Defects Trap: This notification indicates a change in
values of overhead/defect data transmitted from the remote unit. LOSD,
SEGA, PS, and SEGD values are reported.
SHDSL STU-C Up: This trap indicates that the SHDSL STU-C is operationally
up. The trap parameter is the interface name.
SHDSL STU-C Down: This trap indicates that the SHDSL STU-C is
operationally down. The trap parameter is the interface name.
SHDSL Remote ATM Cell Status Response: This trap indicates that remote
ATM Cell status response has been received.
SHDSL UTC received in response of STU-R Config Request: This
notification indicates the remote unit was unable to comply (UTC) with an
STU-R Configuration Request -Management (EOC Message Id 18).
SHDSL UTC received in response of Remote EOC request: This
notification provides a generic unable to comply(UTC) indication. If the remote
unit is unable to comply with a remote EOC request, this trap indicates the
noncompliance of the remote unit.
SHDSL Generic Failure Trap: This notification reports any failure that has