Configuring the Collaboration Function
Collaboration is implemented by establishing reaction entries to monitor the detection results of the
current test group. If the number of consecutive probe failures reaches the threshold, the configured action
is triggered.
Follow these steps to configure the collaboration function:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Enter NQA test group view
nqa entry admin-name
operation-tag
—
Enter test type view of the test
group
type { dhcp | dlsw | dns | ftp
| http | icmp-echo | snmp |
tcp | udp-echo }
The collaboration function is not
supported in UDP jitter and voice
tests.
Configure a reaction entry
reaction item-number
checked-element probe-fail
threshold-type consecutive
consecutive-occurrences
action-type trigger-only
Required
Not created by default.
Exit to system view
quit
—
Configure a track entry and
associate it with the specified
reaction entry of the NQA test
group
track entry-number nqa entry
admin-name operation-tag
reaction item-number
Required
Not created by default.
NOTE:
•
You cannot modify the content of a reaction entry by using the reaction command after the reaction
entry is created.
•
The collaboration function is not supported in a UDP jitter or voice test.
Configuring Threshold Monitoring
Configuration prerequisites
Before configuring threshold monitoring, configure the following:
•
Destination address of the trap message configured with the snmp-agent target-host
command. For more information about the snmp-agent target-host command, see SNMP
Commands in the System Volume.
•
Create an NQA test group and configure related parameters.
Configuring threshold monitoring
Follow these steps to configure threshold monitoring:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Enter NQA test group view
nqa entry admin-name operation-tag
—