8

To do…

Use the command…

Remarks

Enable the trap function globally

snmp-agent trap enable bfd
| bgp | configuration | flash |
ospf [ process-id ] [ ifauthfail |
ifcfgerror | ifrxbadpkt |
ifstatechange | iftxretransmit
| lsdbapproachoverflow |
lsdboverflow | maxagelsa |
nbrstatechange |
originatelsa | vifcfgerror |
virifauthfail | virifrxbadpkt |
virifstatechange |
viriftxretransmit
|
virnbrstatechange ] * |
standard [ authentication |
coldstart
| linkdown | linkup
| warmstart ] * | system |
vrrp
[ authfailure |
newmaster ]

Optional
By default, only the trap function of

the voice module is disabled; and

the trap function of other modules
is enabled.
The bfd keyword is available only
on the H3C SecPath F5000-A5

firewall.

Enter interface view

interface interface-type
interface-number

Required

Enable the trap function of
interface state changes

enable snmp trap updown

Optional
Enabled by default.

CAUTION:

To enable an interface to send linkUp/linkDown traps when its state changes, enable the trap function
of interface state changes on an interface and globally. To enable the trap function on an interface, use
the enable snmp trap updown command. To enable this function globally, use the snmp-agent trap

enable [ standard [ linkdown | linkup ] * ] command.

To make each module generate corresponding traps, enable the trap function with the snmp-agent trap
enable command. The generation of traps by a module may also depend on the configuration of the
module. For more information, see related descriptions of the modules.

Configuring Trap Parameters

Configuration prerequisites

To send traps to the NMS, make the following preparations:

Basic SNMP configurations have been completed. These configurations include version
configuration: community name is needed when SNMPv1 and v2c are adopted; username and

MIB view are needed if SNMPv3 is adopted. Configuration of these parameters must be the same

with that on the NMS.

A connection has been established between the device and the NMS, and they can operate each

other.