H3C Technologies H3C SecPath F1000-E User Manual
Page 74
8
To do…
Use the command…
Remarks
Configure the destination address
for a test operation
destination ip ip-address
Required
By default, no destination IP
address is configured for a test
operation.
Configure the size of probe
packets sent
data-size size
Optional
100 bytes by default.
Configure the filler string of a
probe packet sent
data-fill string
Optional
By default, the filler string of a
probe packet is the hexadecimal
number
00010203040506070809.
Specify a VPN instance
vpn-instance instance
Optional
Not specified by default.
Specify the IP address of an
interface as the source IP address
of an ICMP echo request
source interface interface-type
interface-number
Optional
By default, no interface address is
specified as the source IP address
of ICMP probe requests.
If you use the source ip command
to configure the source IP address
of ICMP echo probe requests, the
source interface command is
invalid.
The interface specified by this
command must be up. Otherwise,
the probe will fail.
Configure the source IP address of
a probe request
source ip ip-address
Optional
By default, no source IP address is
specified.
If no source IP address is specified,
but the source interface is
specified, the IP address of the
source interface is taken as the
source IP address of ICMP probe
requests.
The source IP address must be that
of an interface on the device and
the interface must be up.
Otherwise, the probe will fail.
Configure the next hop IP address
for an ICMP echo request
next-hop ip-address
Optional
By default, no next hop IP address
is configured.
Configure common optional
parameters
Optional