beautypg.com

H3C Technologies H3C SecPath F1000-E User Manual

Page 232

background image

9

To do…

Use the command…

Remarks

Configure the output rules of
system information

info-center source
{ module-name | default }
channel { channel-number |
channel
-name } [ debug { level
severity | state state } * | log
{ level severity | state state } * |
trap { level severity | state

state } * ] *

Optional
Refer to

Default Output Rules of

System

.

Configure the format of the time
stamp

info-center timestamp
{ debugging | log | trap }
{ boot | date | none }

Optional
The time stamp format for log, trap

and debugging information is
date by default.

Enabling the display of system information on the console

After setting to output system information to the console, you need to enable the associated display

function to display the output information on the console.
Follow these steps in user view to enable the display of system information on the console:

To do…

Use the command…

Remarks

Enable the monitoring of system
information on the console

terminal monitor

Optional
Enabled on the console and
disabled on the monitor terminal

by default.

Enable the display of debugging

information on the console

terminal debugging

Required
Disabled by default

Enable the display of log
information on the console

terminal logging

Optional
Enabled by default

Enable the display of trap

information on the console

terminal trapping

Optional
Enabled by default

Outputting System Information to a Monitor Terminal

System information can also be output to a monitor terminal, which is a user terminal that has login

connections through the AUX or VTY user interface.

Outputting system information to a monitor terminal

To do…

Use the command…

Remarks

Enter system view

system-view

Enable information center

info-center enable

Optional
Enabled by default