Tcp test configuration example, Network requirements – H3C Technologies H3C SecPath F1000-E User Manual
Page 102
36
[DeviceA] nqa entry admin test
[DeviceA-nqa-admin-test] type snmp
[DeviceA-nqa-admin-test-snmp] destination ip 10.2.2.2
# Enable the saving of history records.
[DeviceA-nqa-admin-test-snmp] history-record enable
[DeviceA-nqa-admin-test-snmp] quit
# Enable SNMP query test.
[DeviceA] nqa schedule admin test start-time now lifetime forever
# Disable SNMP query test after the test begins for a period of time.
[DeviceA] undo nqa schedule admin test
# Display results of the last SNMP test.
[DeviceA] display nqa result admin test
NQA entry (admin admin, tag test) test results:
Destination IP address: 10.2.2.2
Send operation times: 1 Receive response times: 1
Min/Max/Average round trip time: 50/50/50
Square-Sum of round trip time: 2500
Last succeeded probe time: 2007-11-22 10:24:41.1
Extended results:
Packet loss in test: 0%
Failures due to timeout: 0
Failures due to disconnect: 0
Failures due to no connection: 0
Failures due to sequence error: 0
Failures due to internal error: 0
Failures due to other errors: 0
Packet(s) arrived late: 0
# Display the history of SNMP tests.
[DeviceA] display nqa history admin test
NQA entry (admin admin, tag test) history record(s):
Index Response Status Time
1 50 Timeout 2007-11-22 10:24:41.1
TCP Test Configuration Example
Network requirements
As shown in
, use the NQA TCP function to test the time for establishing a TCP connection
between Device A and Device B. Port 9000 is used.
Figure 10 Network diagram for TCP tests