Outputting system information to the trap buffer – H3C Technologies H3C SecPath F1000-E User Manual
Page 234
11
To do…
Use the command…
Remarks
Enable information center
info-center enable
Optional
Enabled by default
Name the channel with a specified
channel number
info-center channel
channel-number name
channel-name
Optional
Refer to
for default channel
names.
Configure the output rules of the
system information
info-center source
{ module-name | default }
channel { channel-number |
channel-name } [ debug { level
severity | state state } * | log
{ level severity | state state } * |
trap { level severity | state
state } * ] *
Optional
Refer to
.
Specify the source IP address for
the log information
info-center loghost source
interface-type interface-number
Optional
By default, the source interface is
determined by the matched route,
and the primary IP address of this
interface is the source IP address of
the log information.
Configure the format of the time
stamp for system information
output to the log host
info-center timestamp
loghost { date | iso |
no-year-date | none }
Optional
date by default.
Set the format of the system
information sent to a log host to
UNICOM
info-center format unicom
H3C by default.
Specify a log host and configure
the related output parameters
info-center loghost { ipv6
host-ipv6-address |
[ vpn-instance
vpn-instance-name ]
host-ipv4-address } [ port
port-number ] [ channel
{ channel-number |
channel-name } | facility
local-number ] *
Required
By default, the system does not
output information to a log host. If
you specify to output system
information to a log host, the
system uses channel 2 (loghost) by
default.
The value of the port-number
argument should be the same as
the value configured on the log
host, otherwise, the log host cannot
receive system information.
Outputting System Information to the Trap Buffer
NOTE:
The trap buffer receives the trap information only, and discards the log and debugging information even
if you have configured to output them to the trap buffer.