beautypg.com

H3C Technologies H3C SecPath F1000-E User Manual

Page 60

background image

7

To do…

Use the command…

Remarks

Enter system view

system-view

Configure a detection interval

shutdown-interval time

Optional
The detection interval is 30
seconds by default.

Configuring Temperature Alarm Thresholds for a

Card

Configuring Temperature Alarm Thresholds for a Card

You can set temperature alarm thresholds for a card by using the following commands. When the

temperature of a card reaches the threshold, the device generates alarms.
Follow these steps to configure temperature alarm thresholds for a card:

To do…

Use the command…

Remarks

Enter system view

system-view

Configure temperature alarm
thresholds for a card

temperature-limit slot-number

lower-value upper-value

Optional

Clearing the 16-bit Interface Indexes Not Used in

the Current System

In practical networks, the network management software requires the device to provide a uniform, stable

16-bit interface index. That is, a one-to-one relationship should be kept between the interface name and
the interface index in the same device.
For the purpose of the stability of an interface index, the system will save the 16-bit interface index when

a card or logical interface is removed.
If you repeatedly insert and remove different subcards or interface cards to create or delete a large

number of logical interfaces, the interface indexes will be used up, which will result in interface creation

failures. To avoid such a case, you can clear all 16-bit interface indexes saved but not used in the current
system in user view.
After the above operation,

For a re-created interface, the new interface index may not be consistent with the original one.

For existing interfaces, their interface indexes remain unchanged.

Follow these steps to clear the 16-bit interface indexes not used in the current system: