beautypg.com

Dlsw test configuration example, Network requirements – H3C Technologies H3C SecPath F1000-E User Manual

Page 107

background image

41

Packet loss in test: 0%

Failures due to timeout: 0

Failures due to disconnect: 0

Failures due to no connection: 0

Failures due to sequence error: 0

Failures due to internal error: 0

Failures due to other errors: 0

Packet(s) arrived late: 0

Voice results:

RTT number: 4000

Min positive SD: 1 Min positive DS: 1

Max positive SD: 360 Max positive DS: 1297

Positive SD number: 1030 Positive DS number: 1024

Positive SD sum: 4363 Positive DS sum: 5423

Positive SD average: 4 Positive DS average: 5

Positive SD square sum: 497725 Positive DS square sum: 2254957

Min negative SD: 1 Min negative DS: 1

Max negative SD: 360 Max negative DS: 1297

Negative SD number: 1028 Negative DS number: 1022

Negative SD sum: 1028 Negative DS sum: 1022

Negative SD average: 4 Negative DS average: 5

Negative SD square sum: 495901 Negative DS square sum: 5419

One way results:

Max SD delay: 359 Max DS delay: 985

Min SD delay: 0 Min DS delay: 0

Number of SD delay: 4 Number of DS delay: 4

Sum of SD delay: 1390 Sum of DS delay: 1079

Square sum of SD delay: 483202 Square sum of DS delay: 973651

SD lost packet(s): 0 DS lost packet(s): 0

Lost packet(s) for unknown reason: 0

Voice scores:

Max MOS value: 4.38 Min MOS value: 4.38

Max ICPIF value: 0 Min ICPIF value: 0

NOTE:

The display nqa history command cannot show you the results of voice tests. Therefore, to know the result
of a voice test, you are recommended to use the display nqa result command to view the probe results of

the latest NQA test, or use the display nqa statistics command to view the statistics of NQA tests.

DLSw Test Configuration Example

Network requirements

As shown in

Figure 13

, use the NQA DLSw function to test the response time of the DLSw device.